Transformers & Chokes

Transformer - Output, 15W, 8kΩ CT Primary, for Fender® Deluxe 5E3
Paper bobbin output transformer replacement for the Fender® part number 50246 as used in the 5E3 Deluxe Amp. This transformer has an 8kΩ center tapped primary and an 8Ω secondary. Features
  • Paper Bobbin
  • Vintage Style Color Code
  • 8kΩ Center Tapped Primary
  • 8Ω Secondary
  • Standard 3.125” Mounting Centers
Please Log In to view prices
Transformer - Power, 120V Primary, 330V / 6.3VCT / 5V Secondary, for Fender® Deluxe 5E3
Power transformer replacement for the Fender® part number 64526 as used in the 5E3 Deluxe Amp. This transformer accounts for modern mains voltage and will provide a B+ voltage of ~370VDC with 120VAC on the primary in a standard 5E3 build paired with the P-TGO-002 output transformer. This upgraded transformer also features a center tap on the 6.3V filament. Features
  • Provides vintage correct DC voltages in stock 5E3 builds
  • 330V (660 VCT) B+ at 120mA
  • Center tapped 6.3V filament at 2A
  • 5V filament supply at 2A
  • For 120V 60Hz primary
  • Standard 2.8125" x 2.25” mounting centers
Please Log In to view prices
Transformer - Hammond, High Voltage Plate & Filament, Horizontal mount
  • Horizontal mount. For Vertical Mount, see P-T263-X
  • Primary 117 VAC, 50/60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
  • For Vertical Mount, see P-T263-X
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 30V / 60V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 60 V series, 30 V parallel secondary.
Please Log In to view prices
Transformer - Output, 8 W, 4kΩ - 9kΩ impedance
Specifications Output 8 W Primary Impedance 4,000 to 9,000 Ω Mounting Centers 2.375" Weight 0.7 lbs
Please Log In to view prices
Transformer - Hammond, Line European grounded adaptor plug
Special Order Item
European plug type Used in: Austria; Belgium; Finland; France; Germany; Middle East; Netherlands; Norway; Parts of Africa, Asia ,South America, China, Tahiti and Caribbean; Sweden Features:
  • For use with Hammond transformers
  • Heavy duty design with plastic shell & double wipe contacts.
  • Indoor use only.
  • Allows for ground connection between equipment and international power sources.
  • Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.
Please Log In to view prices
Transformer - Hammond, Studio Grade Impedance Matching, 140 Series
Studio grade frequency response: 20 Hz. - 20 Khz. (+/- 1 db, ref. @ 1 Khz.) minimum. Excellent frequency response utilizing a 80% nickel core providing high permeability combined with low losses. Designed for maximum bandwidth, lowest distortion at +10 dbm power level or less. Plated steel cans, adjustable height case bracket.
Please Log In to view prices
Transformer - Hammond, Tube Output, Easy Wire Secondary
  • Designed for push-pull tube output circuits.
  • Enclosed (shielded), 4 slot, above chassis Type 'X' mounting.
  • Frequency response 30 Hz. to 30 Khz. at full rated power (± 1 db max. - ref.
Please Log In to view prices
Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 25 VCT
Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 25V or 25.2V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Global Use, Dual Primary 115/230 VAC
  • Dual primary 115/230 VAC
  • 50/60 Hz. operation
  • Dual secondaries for series or parallel connections
  • 4,000 V RMS Hipot test
  • Class F insulation (155 degrees, C)
  • Chassis mount
  • Dual bobbin construction
  • Dual use terminals
  • C UL US recognized (E207860)
  • TUV Type Approved
  • CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 240 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Please Log In to view prices
Transformer - Isolation, 35 VA, 115V, 300 mA, 1 x 115V
35VA chassis mount Power Transformer for isolating equipment from direct connection to the power line. It is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection under normal or overload conditions between the primary and secondary windings. These units are designed with 1500V isolation between winding to winding and between winding and core. Materials and construction are rated for Class B insulation system.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 60V / 120V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 120 V series, 60 V parallel secondary.
Please Log In to view prices
Transformer - Output, 8 W, Single Ended
Specifications
  • Power: 8 W
  • Primary Impedance: 5,000 Ω single-ended
  • Secondary Impedance: 8 Ω
  • Primary DC Resistance (Red to Blue): 230 Ω
  • Mounting Centers: 2.375"
  • Mounting Type: U-bracket
  • Weight: 0.7 lbs
Please Log In to view prices
Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).
Please Log In to view prices
Transformer - Hammond, Microphone Splitter Transformers
Studio Grade Impedance Matching, 1140 Series. ​Designed with Nickel alloy cores for high performance and Wide Bandwidth. Frequency Response: 20 Hz – 20 kHz ±0.35 dB, (ref. @ 1 kHz). Low distortion at levels up to +27 dBu @ 20 Hz. Excellent Shielding – Mu Metal enclosures
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 12.6 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 117 50/60Hz primary and a 12.6V center tapped secondary
Please Log In to view prices
Transformer - Hammond, Low Voltage, Single Primary, 10V 5A
Special Order Item
Secondary VAC: 10V C.T.
Current: 5 A
VA Rating: 50
Features:
  • Single Primary 115VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
Please Log In to view prices
Transformer - Hammond, Low Voltage / Filament, Open, 22 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 22V center tapped secondary.
Please Log In to view prices
Transformer - Hammond, Radiola III-A Replacement Audio
Developed in response to requests from RCA Radiola III-A collectors. The original transformers are usually found with open" windings due to the fine wire and high turns usedcoupled with age. This is a universal replacement type - it will replace any of the three audio transformers used (1st audio driver2nd audio-phase splitter stage or output transformer)by correctly connectiong the 5 lugs. A pin out and connection diagram is included. The cases from the old transformer will fit this new unit. The terminal board is a duplicate of the original.
Key Features
  • Primary: 4000 turns, #41 wire (lugs 4 & 2)
  • Secondary: 12000 turns C.T., #41 wire (lugs 5 & 1lug 3 is C.T. connection)
  • Termination: Solder lugs on a 1 3/4" x 1" terminal board with 4-5" connecting leads
  • Size: 1-7/8" long x 1-11/16" wide x 1-3/8" deep
  • Lamination Core Size: 5/8" x 1/2"
  • Weight: 7 oz.
Please Log In to view prices
Transformer - Hammond, Guitar Amplifier, replacement for Yorkville / Traynor
  • Replacement for Yorkville/Traynor amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".

Part No. Primary Secondary 1 Secondary 2 Secondary 3 Yorkville / Traynor Amp Yorkville / Traynor Part No VAC Hz. P-T290TRA 120 V 60 Hz. 320 V @ 600 mA 60 V @ 50 mA 6.3 V.C.T. @ 9 A 100 Watt Bass A-1380 P-T290TRB 120 V 60 Hz. 620 V @ 115 mA 6.3 V.C.T. @ 115 mA YBA2-B A-1314 P-T291JX 120 V 60 Hz. 320 V @ 500 mA 60 V @ 20 mA 6.65 V.C.T.
Please Log In to view prices
Choke - One Electron, Audio, PRC-3, 225H for Preamp Output
The PRC-3 audio choke from One Electron was designed as a plate load for the output of either a high quality line amplifier or a phono preamp.
Please Log In to view prices
Transformer - Hammond, Toroidal Power, 110V / 220V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 220 V series, 110 V parallel secondary.
Please Log In to view prices